Solder joint inspection of a PCB with a stereo microscope

Medical device electronics with ISO 13485 quality

We populate, assemble and test electronics for medical devices in an ISO 13485:2016 system certified by SGS. Our longest medical device customer relationship has lasted over 20 years.

SGS ISO 13485 certification mark
Certificate

ISO 13485:2016 – the same system for every order

Our quality system has been certified by SGS Fimko Oy since 2019, and SGS audits it annually. The same system, traceability and nonconformity process apply to every order – including those that are not medical devices.

Certificate number
FI19/5163
Issued by
SGS Fimko Oy
Certified
since 2019
Valid until
18 July 2028
Scope
Electronics contract manufacturing and related services
A guide for medical device manufacturers

What to require from a contract manufacturer – and how it works with us

The EU Medical Device Regulation (EU) 2017/745 requires the manufacturer to control its subcontractors as well. With these eight points in place, supplier evaluation and audits run smoothly.

1 · Certificate

The scope covers contract manufacturing

Check that the certificate covers exactly the work you are buying. Our scope is electronics contract manufacturing and related services.

2 · Suppliers

Controlled component sourcing

Components and PCBs are purchased from approved suppliers in line with the quality system, and purchases are traceable.

3 · Traceability

From the delivery back to the materials

Each delivery's declaration of conformity records the products, quantities and serial numbers, together with the materials used, their suppliers and traceability data. Inspection and test results are archived.

4 · Change control

No changes without your approval

Component substitutions and process and test changes are made only after your approval, and they are documented.

5 · Nonconformities

Root cause and corrective action

Every nonconformity is investigated down to its root cause and reported in a nonconformity report – for manufacturing defects, our target is within two weeks of the product arriving for analysis. The corrective action shows in the following batches.

6 · Audits

The door is open

Customer audits in Kemijärvi are welcome, and SGS audits our system annually.

7 · Agreements

Responsibilities in writing

When we manufacture a product from start to finish, we sign a manufacturing agreement. A non-disclosure agreement is always available on request, and a quality agreement can be made on your own template.

8 · Records

Documents kept for years

Manufacturing records are retained in accordance with the quality system and customer requirements, and they are available for audits.

What we make

From circuit board to tested device

For medical devices we manufacture circuit boards (SMT and THT), control units and finished devices including final testing. Hidden solder joints are inspected by X-ray and every board under the microscope.

Small and medium-sized series are typical for medical devices. We have no minimum order quantity, and the same product can be manufactured unchanged for years – exactly what an approved device needs.

Read the story: a medical device manufacturer for over 20 years →

Changing manufacturer in the middle of the product life cycle?

For a medical device, changing manufacturer is validation work. We carry out the transfer via a pilot batch and first article inspection, and it is worth keeping the old manufacturer running in parallel until the pilot has been approved.

How the transfer works →

Frequently asked questions

Yes. ISO 13485:2016 certificate FI19/5163 issued by SGS Fimko Oy, certified since 2019 and valid until 18 July 2028. Scope: electronics contract manufacturing and related services.
Yes. The transfer goes through a pilot batch and first article inspection. It is worth keeping the old manufacturer running in parallel until the pilot has been approved. Read more about switching EMS provider.
Yes. Customer audits and factory visits in Kemijärvi are welcome – let us agree on a time directly. SGS audits the quality system annually.
Yes. The same ISO 13485 quality system, traceability and nonconformity process apply to all our orders.

Tell us about your device

Send your BOM and estimated annual volume – we will sign a non-disclosure agreement before you send any files, if you need one. We reply within one business day.